9000 Series Transportable Calibrators

9000 Series Transportable Multi-Product Calibrator (25 & 50 ppm)

  • AC/DC Voltage to 1000V
  • AC/DC Current to 30A (1500A with coil)
  • 2 & 4 Wire Resistance to 1G Ohms
  • Capacitance to 10mF
  • Frequency to 10MHz
  • Inductance to 10H
  • Thermocouple Simulation & Measurement
  • PRT Simulation
  • Power Calibration
  • Fully Expandable with External adaptors
  • 9000 Series Transportable Calibrators
OVERVIEWSPECIFICATIONSOPTIONSVIDEOSDOWNLOADS
9041A Precision Multiproduct Calibrators (25ppm) 9050A Entry Level Calibrator (50 ppm)
Designed to be the mainstay of a modern working laboratory : provides over 10 instruments in one unit. Fully expandable for the future. Providing full functionality and 50ppm performance at entry level costs – increase your productivity today!

TRANSPORTABLE MULTI PRODUCT CALIBRATOR Designed to be the mainstay of a modern working laboratory, this 25 ppm calibrator can perform the functions of over 10 calibrators in one fully expandable unit. Built into a robust, transportable enclosure the 9000 Series provides an ideal on-site solution including use on oil / gas platforms, aircraft hangers and other industrial environments. With increasing demand for on site calibrations from your customers, the 9000 series is the obvious choice for your next Multi Product Calibrator.

THE COMPLETE SOLUTION

With thier wide workload capability, full output protection including I-GUARD system, fast warm up time, intuitive front panel design, and easy automation capabilities with Procal Software, the 9000 series Multi Product Calibrators offer unprecedented value in calibration – they are truly the best choice of calibrator for all reasons that matter– PERFORMANCE – PRICE – VERSATILITY.

TRANSMILLE’S 9000 SERIES CALIBRATES

  • UP TO 6.5 DIGIT MULTIMETERS
  • WATT / POWER METERS
  • POWER SUPPLIES
  • HI-POTS
  • DATA LOGGERS
  • 600MHz DIGITAL OSCILLOSCOPES
  • RLC METERS
  • INSULATION TESTERS
  • ELECTROMETERS
  • PRESSURE GAUGES
  • CLAMP METERS
  • AC BRIDGES
  • PROCESS CONTROL CALIBRATORS
  • CURRENT SHUNTS
  • FREQUENCY COUNTERS
Not sure what calibrator is right for you? Check out our workload chart, or give us a call (802) 846 7582, we are always here to help.

 

9041A
9050A
Parameter Range Resolution Accuracy Range Resolution Accuracy
DC Voltage 0 to 1025V 0.1uV 25ppm 0 to 1025V 0.1uV 50ppm
KV amplifier 1 to 10kV 10mV 0.5%
DC Current 0 to 30A 100pA 50ppm 0 to 20A 100pA 0.01%
pA Adaptor 0 to 100uA 0.1pA 200ppm
Amplifier (EA3024) 10 to 100A 100uA 0.08%
AC Voltage 0 to 1020V 1uV 0.035% 0 to 1020V 1uV 0.035%
10Hz to 500kHz 10Hz to 500kHz
DC Voltage 1 to 5kV 10mV 0.8%
AC Current 0 to 30A 1nA 0.06% 0 to 20A 1nA 0.07%
10Hz to 10kHz 10Hz to 10kHz

Amplifier (EA3024)
10 to 70A 100uA 0.08%
Resistance (Passive) 0 to 1GOhm 40ppm 0 to 100MOhm 0.005%
Resistance (Simulated) 10 to 10MOhm 100ppm 0.03%
Capacitance 1nF to 10uF 0.25% 10nF to 1uF 0.4%
Inductance 1mH to 10H 0.50%
Frequency 1Hz to 10MHz 20ppm/1ppm 10Hz to 10MHz 20ppm
Pulse Width / Duty Cycle 10 to 90% 1ppm
9041A Extended Specifications 9050A Extended Specifications

GENERAL SPECIFICATIONS

Temperature
Thermocouple Simulation (EA001)
PRT/RTD (OPTION PRT) (3041/3010)
Types: J, K, T, R, S, B, N, E • Accuracy 0.05°C • CJC: Auto & Manual – Accuracy 0.1°C • Connection Neutral (Copper) Thermocouple Plug
Range: -100°C to 800 °C • Accuracy 0.01%
Oscilloscope Calibration (SCP250/SCP350/SCP600)
Ampltude
Timebase
Leveled Frequency Sweep
Trigger Output
Range: 2mV/Div (12mV Pk-Pk) to 50V/Div (300V Pk-Pk) • 1kHz Square Wave or DC • Accuracy 0.01% ± 20uV
Range: 5s to 2ns (Option SCP600) • 5s to 5ns (Option SCP350/SCP250) • Accuracy 5ppm
Range: 50kHz, 5MHz to 250/350/600MHz (dependant on option installed) • Level : 600mV Pk-Pk into 50 Ohms • Accuracy 0.5dbm
Dedicated BNC trigger output for timing & amplitude waveforms
Power Calibration (PWR50/PWRSINE/PWRDDS)
AC Power
Phase / Frequency Range
DC Power
Power Direct / 50 Turn Coil: 20.8kW / 1.04MW (3050): 30.7kW / 1.53MW (3041/3010) • Accuracy 0.05% ± 3.5mW/Volt
Range: 0 to 359.9° • Resolution 0.1° • Accuracy 0.1° • Frequency Range: 10Hz to 1kHz
Power Direct / 50 Turn Coil: 30.7kW / 1.53MW (3041/3010) • Accuracy 0.04% ± 3.5mW/Volt
Optical Tachometer Calibration (9041)
Optical Tachometer Adapter (EA003) Range: 60RPM to 60,000RPM • Accuracy 50ppm
Power Supply Calibration (9041)
PSU Calibration Adapter EA3023 (EA3025) Voltage Measurement 0 to 63V (100V) • Current Load 0 to 3A (60A)
Pressure Calibration (9041)
Pressure Calibration Modules (TPA001 to TPA018) Range: 25mBar to 700Bar (10,000PSI) • Accuracy From 0.04%
Torque Calibration (9041)
Torque Calibration Adapter (EA014) Range: 0 to 20Nm : Accuracy 0.2%
pA / High Resistance Calibration (9041)
pA / High Resistance Measurement Adapter (EA008)
pA Source Adapter (EA013)
5 Ranges: 10nA to 100uA • Resolution 1pA • Accuracy 0.02% ± 3 Counts
5 Ranges: 10nA to 100uA • Resolution 1pA • Accuracy 0.02% ± 3 Counts
Clamp & Power Meter Calibration
2/10/50 Turn Clamp Coil (EA002) 3 Coils: 2 • 10 • 50 Turn : Magnetically Balanced Design: 10mm (2/10 Turn) 25mm (50 Turn) Internal Dimensions: Accuracy: 0.24%
Multi Function Workstation (EA015) (9041)
Insulation Tester Calibration – Insulation Resistance
Continuity Resistance
Test Voltage MeasurementProcess Control Calibrators
Voltage Measurement
Current Measurement
Voltage, Current & Temperature
Source
Clamp Meter / Temperature / Optical Tachometer
Range: 0 to 2GOhms • Resolution 10kOhm • Max. 1000V • Accuracy 0.2% to 5MOhm, 3% above
Ranges: 1.9, 10, 19, 100, 190, 1kOhms • Accuracy 0.2% ± 50mOhms
Ranges: 50V, 100V, 250V, 500V, 1kV @ 1mA Load • Accuracy 0.5% ± 2 CountsRanges(Resolution): 100mV(1uV), 1V(10uV), 10V(100uV) • Accuracy 0.02% ± 2 Digits
Ranges: 30mA • Accuracy 0.03% ± 2 Digits
See Calibrator Specifications
See Clamp Coil / Thermocouple / Tacho Adapter
Specifications

350 / 600 MHz OSCILLOSCOPE

AC SINE / DC POWER

DIRECT DIGITAL SYNTHESIS POWER

SIMULATED RES / CAP

INDUCTANCE

PRT/RTD

1ppm HIGH STABILITY
CRYSTAL REFERENCE

THERMOCOUPLE SIMULATION & MEASUREMENT

2 / 10 / 50 TURN
CLAMP COIL ADAPTERS
(30A & 40A MODELS)

OPTICAL TACHOMETER ADAPTER

pA / HIGH RESISTANCE MEASUREMENT ADAPTER

TORQUE MEASUREMENT ADAPTER

TORQUE MEASUREMENT ADAPTER

MULTI FUNCTION WORKSTATION

HUMIDITY & TEMPERATURE MEASUREMENT

4 CHANNEL SCOPE TEST HEAD

100A DC / 70A AC TRANSCONDUCTANCE AMPLIFIER

3A / 63V POWER SUPPLY CALIBRATION ADAPTER

10kV DC / 5kV AC KILOVOLT AMPLIFIER

60A / 100V POWER SUPPLY CALIBRATION ADAPTER

PRESSURE MEASUREMENT ADAPTERS

PRECISION ANALOGUE LEAD SET

 

OPTION SCP350/600

Three options are available for the 3000 Series calibrators which are suitable for calibration of both analogue and digital storage oscilloscopes :

  • 250MHz (SCP250) : 3050
  • 350MHz (SCP350) : 3041 / 3010
  • 600MHz (SCP600) : 3041 / 3010

All options provide the calibration waveforms required for amplitude, timebase and bandwidth including gain and linearity of the horizontal and vertical deflection circuits. To minimise lead changing, the oscilloscope signals are output from a single BNC connector – for automated calibration and optional 4-channel test head adapter is available.

 

OPTION PWRSINE

The AC Sine / DC power calibration option provides cost effective calibration of power (Watts) and VA ranges on power meters and clamp meters. The power option provides both voltage and current outputs simultaneously (phantom load) with an adjustable phase relationship.

Any voltage up to 1025V can be set using the normal output ranges and specifications of the calibrator. Currents up to 30A are available from the output of the calibrator without the need for an external amplifier.

The power function is very easy to use – select ‘power’ from the soft key menu, connect the power meter to both the voltage and current terminals and enter the voltage, current and frequency. Phase angle can be adjusted using the softkeys with a resolution of 0.1°. Power output is automatically calculated and displayed in kW.

 

OPTION PWRSINE

The Direct Digital Synthesis (DDS) power option for the 3041 and 3010 calibrators extends the AC Sine / DC power function to provide generation of waveforms with harmonic content for calibrating power meters with power harmonics functions. This includes a set of five fixed waveforms, plus the ability to upload user defined waveforms from a PC allowing waveforms with custom harmonic content to be generated.

 

OPTION SIMRC

For dependable readings regardless of the measurement technique and the ultimate in performance, the 3000 series uses precision passive resistors and capacitors, with calibrated values for both 2 and 4 wire connections. Using passive standards also allows confident calibration of AC bridges and removes any difficulty with traceability.

For the 3010 and 3041 a simulated option is available for resistance values
between cardinal points providing a continuous range from 10 Ohms to 10 MOhms, with decade capacitance points up to 10 mF.

 

OPTION IND

By incorporating this useful option, the workload of the 3000 Series calibrators can be increased to support calibration of RLC (REsistance / Capacitance / Inductance) meters and bridges and also allows calibration of DMMs with inductance measurement
ranges.

Incorporating 8 fixed values, including 19mH and 29mH values for ‘3’ range meters this option allows testing of these types of meters at points which can verify their linearity at near full scale points.

 

OPTION PRT

The RTD/PRT option makes calibration of high accuracy resistance thermometers easy. Simply connect in place of the probe and compare the displayed value with the 3000 Series calibrator. As the calibrator used passive precision resistors, reliable readings are guaranteed regardless of the measurement technique used by the thermometer.

 

OPTION FRQ

Ideal for supporting the calibration of frequency counters / meters, the high stability crystal option provides improved accuracy to 1ppm.

 

EA001A

A superior thermocouple simulation & Measurement option, using an external adapter. Temperature gradients / thermal EMFs which can be introduced by internally mounted thermocouple simulation methods are one of the greatest sources of error with thermocouple temperature calibration.

For the ultimate in accuracy, Transmille has designed a dedicated external adapter. This keeps the electronics required to generate the low level signals as close as possible to the measuring input of the thermometer. This also allows the signal to be as free as possible from electrical noise, and also eliminates errors caused by heat generated by surrounding electronics in the calibrator.

  • Direct simulation & Measurement of 8 Thermocouple types
  • CJC sensor built into the thermocouple plug –
    Measures the CJC temperature at the closest point to the
    cold junction.

Special care has been taken over the cold junction compensation – a common source of errors in thermocouple calibration. the cold junction compensation (CJC) sensor is mounted in the thermocouple plug itself. By measuring the cold junction at the instruments input allows any type of thermocouple to be simulated without using compensation cables.


EA002 / EA019

Designed for the calibration of both wound AC and magnetic field hall effect AC/DC clamp meters the Transmille current coil offers several unique features built in a robust construction, complete with alignment table for ease of use.

  • Calibrates clamp meters up to 1500A (30A input)
  • 2 / 10 / 50 Turn Coils
  • High accuracy AC/DC balanced design
  • Wide range of clamp sizes covered
  • Includes alignment table for repeatable readings

Three coils in one provide the ability to calibrate a wide range of coils,
from small lower clamps down to 10mm jaw diameter to larger current clamps.

 

EA003

Using a high intensity LED light source, optical tachometers can be calibrated quickly and easily. Simply enter the RPM value using the calibrator keypad or use ProCal software for automated calibration.

  • High intensity LED light source
  • Direct keyboard input in RPM
  • Range 60 to 60,000 RPM


EA008

The high resistance / pA measurement adapter eliminates the need for a separate electrometer instrument. The low cost EA008 provides 5 current measurement ranges down to 10nA with a resolution of 1pA and incorporates a ‘virtual ground’ input., avoiding errors due to input impedance.

  • Accurate current measurement down to pico amp levels
  • deal for high value resistance measurement to 1 TOhm
  • Five range from 10nA to 100uA
  • Supplied with Virtual Front Panel software

 

EA013

Provide accurate calibration of sensitive electrometers and low level pico amp meters safely and quickly with this purpose designed option.

A unique and ingenious circuit designed to convert the accurate voltage output from the calibrator into low noise precision current without the use of destructive high voltages and unstable high resistors often used.

  • Ideal for calibrating electrometers
  • Source accurate current down to pA levels
  • Low open circuit compliance voltage
  • Safe to use on sensitive input circuits
  • Supplied with VFP software

 

EA014

By connecting a torque calibration adapter to the 3000 Series calibrator, torque calibration can be performed. Housing an external torque transducer allow torque screwdrivers up to 20Nm to be calibrated.

  • Accuracy 0.2%
  • Supports multiple units eg. Nm, ftlb etc.

 

EA015

The multi function workstation adapter provides a central work area with all the connections routed conveniently to remote terminals mounted at the front of the adapter. The adapter extends the functionality of the calibrator to include :

  • 2 / 10 / 50 Turn Clamp Coil
  • Insulation Resistance Calibration
  • Continuity Resistance Calibration
  • Insulation Test Voltage Measurement
  • Continuity Current Measurement
  • Optical Tachometer Calibration
  • Thermocouple Simulation
  • Voltage Measurement to 30V
  • Current Measurement to 30mA
  • Calibrator Output Routing (to Workstation Front Panel)

 

EA016

Ideal for monitoring laboratory environment the EA016 incorporates temperature and humidity sensors.

  • Humidity measurement 10% to 90%
  • Temperature measurement 0°C to 50°C

 

EA017

For automation of oscilloscope calibration, a 4 channel switching test head is available. Connect to the 3000 series adapter interface and select the channel required. For accurate calibration of 50 Ohm input oscilloscopes up to 1V/Div a low impedance buffered amplitude output can be selected.

  • 4 Channels
  • Direct / Buffered (Typically 0.5 Ohm) Output

 

EA3012

The EA3012 is a powerful linear transconductance amplifier designed exclusively for use with the 3000 Series calibrators which provides a cost effective solution to calibrating high current instruments.

Connecting to the 3000 Series adapter interface, the EA3013 extends the output current range to 100A DC / 75A AC – higher currents are available by paralleling EA3012 amplifiers as required to give the current output needed.

  • 100A DC / 75A AC
  • Stackable for higher currents
  • Low noise linear MOSFET technology
  • Controlled using ProCal or Virtual Front Panel software
  • Ideal for calibrating high current shunts / meters

 

EA3023

An essential option for simplifying calibration of power supplies, the EA3023 can measure the output voltage and also provide an electronic current load allowing voltage, current and even output resistance to be calibrated using a single compact adapter.

Connecting to the 3000 Series adapter interface, the EA3023 is controlled using either ProCal or the supplied Virtual Front Panel software.

  • Measures voltage up to 63V
  • Active current load to 3A
  • Measures output resistance (using VFP software)

 

EA3024

The EA3024 kilovolt amplifier provides the solution to the calibration of high voltage probes and dividers. the amplifier/calibrator combination is used with Virtual Front Panel software to control outputs up to 10kV DC and 5kV AC.

  • 1kV to 10kV DC
  • 1kV to 5kV AC
  • Operated using ProCal or Virtual Front Panel software

 

EA3025

The EA3035 provides an easy to use solution for the calibration of high current power supplies, overcoming many of the problems normally associated with measuring high current outputs.

Key Advantages:

  • Accurate, stable electronic load regardless of power supply output voltage
    and lead connection resistance.
  • Removes the need for specific value high power resistors
  • Allows automation for more efficient calibration

Features :

  • Voltage measurement to 100V
  • Active current load to 60A
  • Output resistance measurement
  • Applications include battery & UPS testing
  • Operated using ProCal or Virtual Front Panel software

 

TPAxx

The 3000 Series supports pressure calibration using a range of pressure modules which connect directly to the calibrator. The pressure modules cover a wide range – an optional hand pressure pump is available as an option to generate pneumatic pressure up to 60Bar and vacuum to -0.95Bar.

  • Operated using ProCal or Virtual Front Panel software
  • Accuracy to 0.04%
  • Optional hand pressure pump

 

OPTION 3000LEAD

A comprehensive set of test leads and adapters is provided in this option lead set to cover requirements from low level DC through to high current and high resistance measurements.

The leads and materials supplied in this measurement set have been carefully selected to minimise connection / lead errors. The safety of the lead set is ensured by the use of non-retractable shrouded connectors for the voltage lead set.

 

?